Roof Pitch Calculator

Use this roof pitch calculator to turn rise and run into your pitch in x/12, degrees, slope % and slope factor, plus the common rafter length for your span — every format a roofer, framer or shingle warranty might ask for. Not the price, not the area — just the slope itself.

One roof…9 in rise / 12 in run
As pitch9/12
As angle36.9°
As slope75% · factor ×1.250

Roof Slope Calculator: Your Roof Slope

Results update as you type — no button to press.

LIVE
A · Enter it your way

Units don't matter — 9 in over 12 in, 9 ft over 12 ft and 22.5 cm over 30 cm are all the same 9/12 pitch. Only the ratio counts.

B · Quick-pick a pitch
C · Rafter length (optional)

For a gable roof, each common rafter covers half the building width plus the overhang. Ridge board thickness and birdsmouth cuts come off this theoretical length — your framer makes those deductions.

Roof cross-section — drawn to your numbers

Standard pitch
RUN 12 RISE 9 36.9° 9/12
Your roof pitch
9/12

For every 12 inches the roof runs horizontally, it rises 9 inches.

Standard pitch · 4/12 to 9/12
Angle36.9°
Degrees from horizontal — what a speed square reads.
Slope75%
Rise as a % of run — the “grade” engineers use.
Slope factor×1.250
Run × this factor = true rafter length along the slope.
Rafter per ft of run15.00 in
Inches of rafter for every 12 in of horizontal run.
Common rafter length17.50 ft
17 ft 6.0 in — half span + overhang, before cuts.
Rise over half span9.75 ft
Height from wall top plate to ridge, on your span.
Shingles are fine here. A 9/12 sits at the top of the standard range — asphalt shingles, metal, tile and slate all work with normal installation rules.
Reference chart

Roof pitch chart: 1/12 to 24/12

Every standard pitch converted to angle, slope % and slope factor, plus the 18/12 and 24/12 rows for steep mansard and A-frame roofs. The row nearest your pitch is highlighted as you use the calculator — screenshot this chart and you can convert any pitch on a job site without the tool.

PitchAngleSlopeSlope factorRafter per 12″ runCategory
1/12Nearly flat4.76°8%×1.00312.04 inNearly flat
2/12Low slope9.46°17%×1.01412.17 inLow slope
3/12Low slope14.04°25%×1.03112.37 inLow slope
4/12Standard pitch18.43°33%×1.05412.65 inStandard pitch
5/12Standard pitch22.62°42%×1.08313.00 inStandard pitch
6/12Standard pitch26.57°50%×1.11813.42 inStandard pitch
7/12Standard pitch30.26°58%×1.15813.89 inStandard pitch
8/12Standard pitch33.69°67%×1.20214.42 inStandard pitch
9/12Standard pitch36.87°75%×1.25015.00 inStandard pitch
10/12Steep pitch39.81°83%×1.30215.62 inSteep pitch
11/12Steep pitch42.51°92%×1.35716.28 inSteep pitch
12/12Steep pitch45.00°100%×1.41416.97 inSteep pitch
18/12Very steep56.31°150%×1.80321.63 inVery steep
24/12Very steep63.43°200%×2.23626.83 inVery steep

Slope factor (also called the pitch multiplier) converts a horizontal run into the length measured along the slope: 14 ft of run under a 9/12 roof needs 14 × 1.250 = 17.50 ft of rafter. The rafter column is that same hypotenuse over a 12-inch run, before ridge and birdsmouth deductions.

Why pitch matters

Which roofing materials your pitch allows

Pitch is not a style choice — it decides what can legally and safely go on the roof. Shingles shed water by overlap, not by being waterproof, so below certain pitches water backs up under them. Check your pitch against this table, then against the IRC R905 minimums by covering in the next section.

Pitch rangeCategoryWorks wellWatch out
0.25/12 – 2/12Nearly flatMembrane (TPO / EPDM), modified bitumen, built-up roofing, standing-seam metal rated for low slopeAsphalt shingles are not allowed — water ponds and migrates under laps
2/12 – 4/12Low slopeMetal panels, rolled roofing; shingles only with full ice-and-water shield or double underlaymentStandard single-underlayment shingle jobs fail early here — and most warranties exclude them
4/12 – 9/12StandardAsphalt shingles, metal, concrete/clay tile, slate, cedar shake — the full menuTile and slate are heavy: confirm the framing is rated for the load
9/12 – 12/12SteepShingles with 6 nails per shingle, metal, slate with extra fasteningNot walkable without roof jacks and harnesses — plan access and fall protection before anyone goes up
Over 12/12Very steepSiding-style applications, mansard cladding, standing seamSnow and ice shed fast and land hard — plan gutters and snow guards

The code minimum for each covering is listed in the IRC R905 table below (asphalt shingles: 2/12 absolute minimum with double underlayment, 4/12 for standard application). A manufacturer's installation manual can require a steeper pitch than code — where the two differ, the steeper figure governs.

Code minimums — IRC R905

Minimum roof pitch by covering: IRC R905

Section R905 of the International Residential Code (Roof Assemblies) sets the shallowest slope each covering may be installed on. Find your pitch in the calculator above, then check it against the covering you want — if your pitch is below the covering's minimum, that covering is not a code-compliant option on your roof.

Roof coveringIRC sectionMinimum pitchConditions
Asphalt shinglesR905.22/12From 2/12 to under 4/12, double underlayment is required (R905.1.1). At 4/12 and over, standard single-underlayment application applies.
Clay & concrete tileR905.32½/12From 2½/12 to under 4/12, double underlayment is required (R905.1.1).
Metal roof shinglesR905.43/12Installed over solid sheathing with underlayment per R905.1.1.
Mineral-surfaced roll roofingR905.51/12Laps cemented and fastened per the manufacturer's instructions.
Slate shinglesR905.64/12Steepest shingle-type minimum in R905 — slate relies on slope to shed water.
Wood shinglesR905.73/12Solid or spaced sheathing; exposure limits tighten as pitch drops.
Wood shakesR905.83/12Interlayment felt required between courses.
Built-up roofingR905.9¼/12Coal-tar built-up roofs are the one exception, permitted down to ⅛/12.
Metal panels — standing seamR905.10¼/12The sealed seam is what allows panel metal to run this shallow.
Metal panels — lapped, with sealantR905.10½/12Lapped, non-soldered seams with lap sealant applied.
Metal panels — lapped, no sealantR905.103/12Without sealant the lap alone must shed water, so the minimum jumps to 3/12.
Modified bitumenR905.11¼/12Membrane system — positive drainage still required.
Thermoset single-ply (EPDM)R905.12¼/12Membrane system — positive drainage still required.
Thermoplastic single-ply (TPO / PVC)R905.13¼/12Membrane system — positive drainage still required.
Sprayed polyurethane foamR905.14¼/12Foam plus protective coating, applied to a sloped deck.
Photovoltaic shinglesR905.172/12Same floor as the asphalt shingles they replace.

Source: International Residential Code, §R905 (Roof Assemblies) and §R905.1.1 (underlayment). These are code minimums, not recommendations — a manufacturer's installation instructions can require a steeper pitch, and local amendments vary, so confirm with your building department before ordering a covering.

Get the numbers

How to measure a roof pitch you already have

You don't need to climb anything to get an accurate rise and run. All three methods measure the same triangle — pick the one that matches what you can safely reach.

01

From the attic — most accurate

Hold a level against the underside of a rafter and mark 12 inches along it from where it meets the rafter. Measure straight down from that mark to the rafter — that vertical distance is your rise. No weather, no shingle thickness, no guessing.

02

With a speed square — on the roof

Hook the square's lip over the top edge of a rafter tail or the ridge, let the pivot point settle, and read the “common” scale where the edge crosses. That number is the x in x/12 directly. Only do this if you can already work on the roof safely.

03

Phone level — from the ground

Stand at the gable end, hold your phone's edge along the rake (the sloped trim board) and read the angle from an inclinometer app. Enter it under Angle ° above. Accurate to about half a pitch step — good enough to identify the roof and check it against the R905 minimums.

The maths, in the open

Pitch to Angle Calculator: Roof Pitch Formulas

Nothing here is a black box — this roof pitch calculator runs on one right triangle, rise, run and rafter, and every number on this page comes from these four formulas.

Pitch
pitch = (rise ÷ run) × 12

A 5-inch rise over a 12-inch run is a 5/12. Measured over any other run, scale it: 10 inches of rise over 24 of run is the same 5/12.

Angle
angle = arctan(rise ÷ run)

Arctan converts the ratio into degrees. 9/12 → arctan(0.75) = 36.87°. This is the number a speed square, saw bevel and inclinometer all speak.

Slope factor
factor = √(1 + (rise ÷ run)²)

Pythagoras in disguise: the rafter length over a 1-unit run. Multiply a horizontal run by it to get the true length along the slope — at 9/12, each foot of run takes 1.25 ft of rafter.

Rafter length
rafter = run × slope factor

Use the full horizontal run the rafter covers — half the building span plus the overhang. 14 ft of run at 9/12 → 14 × 1.250 = 17.50 ft of rafter.

Worked example

A 9/12 roof on a 26 ft wide house, by hand

The calculator's default numbers, worked step by step so you can check them with a pencil.

1 · The ratio9 ÷ 12 = 0.75

Rise 9 in over run 12 in. Slope = 0.75 × 100 = 75%, and the pitch is 9/12.

2 · The angle36.87°

arctan(0.75) = 36.87° — the bevel setting for every rafter cut on this roof.

3 · The factor×1.250

√(1 + 0.75²) = √1.5625 = 1.250. Each foot of run needs 12 × 1.250 = 15.00 in of rafter.

4 · The rafter17.50 ft

Half the 26 ft span is 13 ft, plus a 12 in overhang = 14 ft of run. 14 × 1.250 = 17.50 ft — 17 ft 6 in of common rafter, and the ridge sits 13 × 0.75 = 9.75 ft above the wall plate.

Avoid these

Four pitch mistakes that cost money

✕ Reading slope % as degrees

A 50% slope is 26.6°, not 50°. Percent and degrees only agree at 0. A full 45° roof is a 100% slope — a 12/12. Mixing these up doubles or halves every angle you cut.

✕ Measuring over the shingles

Tape laid on the roof surface includes shingle thickness and any sag, and it measures the rafter, not the rise. Measure the triangle — level plus vertical — from the attic or a rafter tail instead.

✕ Forgetting the overhang in rafter length

A rafter doesn't stop at the wall. Half-span alone gives a rafter that's a foot or more short on a typical eave — order on half span + overhang, then deduct for the ridge board and birdsmouth.

✕ Assuming both sides match

Dutch gables, additions and older framing often carry different pitches on each slope. Measure both sides before ordering — a 6/12 main roof with a 4/12 addition is common, and one number won't roof both.

Questions

Roof pitch — frequently asked questions

What is a 9/12 pitch in degrees?
A 9/12 pitch is 36.87°. The roof rises 9 inches for every 12 inches of horizontal run, and arctan(9 ÷ 12) = 36.87°. It sits at the top of the standard range — steep enough to shed snow and water fast, and high enough that slate, tile and shingles all meet their IRC R905 minimums with room to spare.
What pitch is a 30-degree roof?
tan(30°) = 0.577, and 0.577 × 12 = 6.93 — so a 30° roof is just under 7/12. Builders would frame it as a 7/12 (30.26°) and the difference is inside normal framing tolerance.
What is the difference between pitch and slope?
They describe the same steepness in different units — this roof pitch calculator shows both side by side. Pitch is rise over a 12-unit run (9/12). Slope is the same ratio as a percentage (75%). Strictly, old carpentry used “pitch” for rise over the whole span — but on modern plans, labels and product specs, x/12 is what everyone means.
What is the minimum pitch for asphalt shingles?
2/12 is the absolute minimum under IRC R905.2. Between 2/12 and 4/12, R905.1.1 requires double underlayment, and many warranties demand it in writing; 4/12 and over is the standard single-underlayment application. Below 2/12, shingles are off the table entirely: use membrane or low-slope metal.
What are the IRC R905 minimum pitches for other roof coverings?
Under IRC R905: slate 4/12 (R905.6), metal roof shingles 3/12 (R905.4), wood shingles and wood shakes 3/12 (R905.7 / R905.8), clay and concrete tile 2½/12 (R905.3), mineral-surfaced roll roofing 1/12 (R905.5), and the membrane and panel systems — standing-seam metal, built-up, modified bitumen and single-ply — down to ¼/12 (R905.9–R905.13). The full table is in the IRC R905 section above.
What is a slope factor (pitch multiplier) used for?
It converts a horizontal run into the true length measured along the slope — most often a rafter length. Multiply the run by the factor for your pitch: 14 ft of run × 1.250 (9/12) = 17.50 ft of common rafter. The same factor gives the rafter length for every foot of run — 15.00 inches at 9/12.
What is the most common roof pitch for a house?
Most US homes sit between 4/12 and 9/12, with 6/12 the single most common. Ranch and modern builds lean 3/12–5/12; traditional, Cape Cod and snow-country homes run 8/12–12/12 so snow slides and attic space grows.