40 × 30 ft attic · 1,200 sq ft · adding R-49.
Air-seal before you insulate. An hour with a foam gun sealing top plates, pipe penetrations and the attic hatch stops warm air leaking around the insulation — bypasses can waste more heat than thin insulation does. And keep blown insulation back from soffit vents with baffles, or the roof deck grows mould.
How This Insulation Calculator Works
Insulation is bought to deliver an R-value over an area, so this insulation calculator starts with the only subtraction that matters: the R you need minus the R you already have. R-values stack — sound R-11 batts under R-49 of new blown-in give you R-60, and removing the old layer would buy you nothing but a skip hire. The calculator then divides the job by what one package actually delivers: for loose fill, a bag's coverage shrinks as the target depth grows, so bags are worked out from the bag's total R-coverage, not a fixed sq ft figure. For batts and boards it divides the area by the package coverage and adds a second layer when one product cannot reach the target alone. Every count then gets your waste allowance — 5% by default, the bottom of the 5–10% range installers work to — before it is rounded up to whole packages. If you measured your existing insulation with a ruler rather than a label, use the depth fields: existing R is worked out depth-first, as depth × R per inch.
Cost follows the same split as the material: packages times the package price, plus labour per square foot if a pro installs it — stated both ways, as a rate and as a share of the total (on the default job, labour is $900 of $2,648, or 34%). Blown-in labour is the cheapest per sq ft because a machine does the placing; rigid board is the dearest because every sheet is cut, fitted and taped by hand. A heat-loss model then turns the R-change into an estimated annual heating saving and a simple payback, set out in the savings section below.
R to add = target R − existing R · existing R (depth-first) = measured depth × R per inch
Depth to add (loose fill) = R to add ÷ R per inch
Bags (blown-in) = area × R to add ÷ bag yield × (1 + waste %) — rounded UP
Packages (batts) = area × (1 + waste %) ÷ coverage per package × layers — rounded UP
Sheets (boards) = area × (1 + waste %) ÷ 32 sq ft per sheet × layers — rounded UP
Total = packages × price + (area × labour $/sq ft if pro)
Heat saved (therms/yr) = area × HDD × 24 × (1/R before − 1/R after) ÷ 100,000
Payback (years) = total cost ÷ (heat saved × heat price $/therm)
Recommended R-Value by Climate Zone
These are the ENERGY STAR recommended levels (aligned with IECC 2021) that the insulation calculator above loads when you pick a zone — your zone's row is highlighted, and the column for the space you selected is marked. The attic column is the level for an uninsulated attic: R-30 in Zone 1, R-49 in Zones 2–3 and R-60 in Zones 4–8. The calculator subtracts whatever R you already have from that target, so a top-up is only ever priced for the R still missing. New-build code minimums and local amendments can differ; when they do, the code figure wins.
| Climate zone | Attic | Wall cavity | Floor |
|---|---|---|---|
| Zone 1 — Miami, Hawaii | R-30 | R-13 | R-13 |
| Zone 2 — Houston, Phoenix | R-49 | R-13 | R-13 |
| Zone 3 — Atlanta, Las Vegas | R-49 | R-20 | R-19 |
| Zone 4 — New York, Kansas City | R-60 | R-20 | R-19 |
| Zone 5 — Chicago, Boston | R-60 | R-20 | R-30 |
| Zone 6 — Minneapolis | R-60 | R-21 | R-30 |
| Zone 7 — Duluth | R-60 | R-21 | R-38 |
| Zone 8 — Fairbanks | R-60 | R-21 | R-38 |
Blown-In Insulation Calculator: R-Value per Inch, by Material
R per inch is what turns a target R-value into a depth — and depths are what joist bays, wall cavities and bags-per-job are made of. The last two columns are live: they use the R you still need and the area currently set in the calculator.
| Material | R per inch | Depth for your R to add | Packages for your job |
|---|---|---|---|
| Fiberglass batt (R-19 product) | 3.4 | 14.4 in | 33 packages |
| Blown-in fiberglass | 2.5 | 19.6 in | 46 bags |
| Owens Corning AttiCat (blown fiberglass) | 2.9 | 16.9 in | 32 bags |
| Blown-in cellulose | 3.7 | 13.2 in | 89 bags |
| Mineral wool batt (R-23 product) | 4.2 | 11.7 in | 96 packages |
| XPS foam board | 5.0 | 9.8 in | 200 sheets |
| Polyiso foam board | 6.5 | 7.5 in | 160 sheets |
Board insulation wins on R per inch and loses on labour and price per R — it earns its place on basement walls, rim joists and cathedral ceilings where depth is limited, not spread across a whole attic. Loose fill is the opposite trade: the lowest R per inch, the lowest cost per R over a big open area.
Manufacturer Coverage Chart — Owens Corning AttiCat
Bag counts are only as good as the chart on the bag, and bags are not interchangeable: an AttiCat bag covers far more than the standard 28 lb bag the calculator prices by default (about 1,960 sq ft of R-1 coverage per bag, against 1,350). This is Owens Corning's published AttiCat chart for blown fiberglass in an open attic — the calculator's AttiCat material option works to the same figures, before the waste allowance.
| Target R-value | Blown depth | Bags per 1,000 sq ft | Bags per 1,200 sq ft |
|---|---|---|---|
| R-38 | 13.5 in | 19 bags | 23 bags |
| R-49 | 17.0 in | 25 bags | 30 bags |
| R-60 | 20.5 in | 31.5 bags | 38 bags |
Two lessons in that chart. First, depth and bag count rise together — R-60 is not a rounding-up of R-49, it is 26% more bags. Second, AttiCat reaches R-49 at 17 in where generic blown fiberglass at R-2.5 per inch needs 19.6 in: the products are blown to different densities, which is why the manufacturer's own chart — never a generic R-per-inch rule — governs the product you actually buy. For a top-up, read the chart for the R you are adding: adding R-49 over 1,200 sq ft takes the R-49 row, 30 bags (32 with the 5% waste allowance).
Insulation Cost Calculator: Cost to Insulate by Area (Pro, 2026)
Each row is priced with the space, zone, R-values, material and prices currently set in the calculator — change any of them and this table updates with it. The row nearest your area is highlighted.
| Area | R to add | Packages | Material | Total pro cost |
|---|---|---|---|---|
| 500 sq ft — small attic / one floor | R-49 | 20 bags | $760 | $1,135 |
| 800 sq ft — bungalow | R-49 | 31 bags | $1,178 | $1,778 |
| 1,200 sq ft — average house | R-49 | 46 bags | $1,748 | $2,648 |
| 1,800 sq ft — large house | R-49 | 69 bags | $2,622 | $3,972 |
| 2,500 sq ft — two-storey footprint | R-49 | 96 bags | $3,648 | $5,523 |
Attic Insulation Calculator: Worked Example — Topping Up a 40 × 30 ft Attic in Zone 5
Area: 40 × 30 = 1,200 sq ft. Target: Zone 5 attic (uninsulated basis, ENERGY STAR / IECC) = R-60. The attic already holds old 3½ in batts worth R-11, dry and sound, so they stay: R to add = 60 − 11 = R-49. Material: blown-in fiberglass at R-2.5 per inch → depth to add = 49 ÷ 2.5 = 19.6 in, for 24.0 in total over the ceiling. Bags: one 28 lb bag delivers about 1,350 sq ft of R-1 coverage, so at R-49 it covers 1,350 ÷ 49 = 27.6 sq ft → 1,200 ÷ 27.6 = 43.6 bags, plus the 5% waste allowance = 45.7 → buy 46 bags. Material cost: 46 × $38 = $1,748. Labour: 1,200 × $0.75 = $900 — 34% of the total. Total with a pro: $2,648 — $2.21 per sq ft. Done DIY the same attic is $1,748, and the blower is typically lent free with the bag purchase (standalone rental ≈ $75 a day). Insulating the same attic from empty (R-0) would take 56 bags and cost $3,028 installed — the existing R-11 is worth $380 of bags and an hour of removal labour you never spend. The heat-loss model below puts this job's heating saving at about $170 a year in Zone 5 — a simple payback of 15.6 years pro, 10.3 years DIY, before counting summer cooling savings and comfort.
Annual Saving & Payback — the Heat-Loss Model
Heat flows through a ceiling in proportion to its U-value, 1/R — which is why the first insulation you add saves far more than the last. The model is the standard degree-day heat-loss calculation, run with the heating degree days for your zone and the heat price you set in the calculator:
Annual saving = (heat loss before − heat loss after) × heat price
Simple payback = job cost ÷ annual saving
Worked savings example — 400 sq ft ceiling, Zone 4, adding R-19: Zone 4 runs about 4,600 HDD and heat is priced at $1.30 per therm; the job costs $420. Over an empty cavity (the bare ceiling assembly counts as ≈ R-3, so the model runs R-3 → R-22) the saving is about $166 per year — the $420 pays back in about 2.5 years. Over existing R-11 (R-11 → R-30) the same layer saves only about $32 per year — payback stretches to about 13 years. Same bags, same attic, five times the saving: what you start from matters more than what you add. That is also why the Zone 5 worked example above — already starting at R-11 and pushing all the way to R-60 — shows a longer payback: it is buying the last, least-productive R on the curve, for comfort, condensation control and code-level performance as much as for the energy bill. The model counts heating only; in Zones 1–3 the same insulation also cuts cooling, which shortens real paybacks there.
Sources & Assumptions
Every figure this page uses, where it came from, and the date it was last checked. Reviewed 26 November 2026.
| Item | Assumption used | Source / basis |
|---|---|---|
| Attic R targets | R-30 Zone 1 · R-49 Zones 2–3 · R-60 Zones 4–8 (uninsulated attic) | ENERGY STAR recommended insulation levels, aligned with IECC 2021 |
| Wall & floor R targets | Wall R-13 / R-20 / R-21 and floor R-13 / R-19 / R-30 / R-38 by zone, as tabled above | ENERGY STAR / IECC guidance for existing homes |
| Heating degree days | Z1 700 · Z2 1,700 · Z3 2,800 · Z4 4,600 · Z5 6,100 · Z6 7,500 · Z7 8,800 · Z8 11,500 per year | Representative city per zone, NOAA climate normals |
| Heat price | $1.30 per therm delivered (editable) | 2026 US residential natural-gas benchmark |
| Empty-cavity assembly | ≈ R-3 (ceiling board + air films) in the heat-loss model | Standard assembly values used in degree-day models |
| Labour rates | Blown-in $0.75/sq ft · batts $0.85 · rigid board $1.15 — 34% of the default pro total | 2026 national installer benchmarks |
| Waste allowance | 5% default, applied to all package counts; typical range 5–10% | Installer practice; rival calculators allow the same 5–10% |
| Generic bag yields | Fiberglass 1,350 sq ft·R per 28 lb bag · cellulose 700 per 25 lb bag | Standard manufacturer coverage charts |
| AttiCat coverage | R-38: 19 bags/1,000 sq ft at 13.5 in · R-49: 25 at 17 in · R-60: 31.5 at 20.5 in | Owens Corning AttiCat published coverage chart |
| Blower rental | Free 24 h with minimum bag purchase (often 10 bags); ≈ $75/day standalone + deposit | Big-box rental desks, 2026 benchmark |
| Package prices | As labelled per material in the calculator, all editable | 2026 national retail benchmarks |
Four Insulation Mistakes That Waste the Money You Just Spent
Ripping out sound old insulation
R-values add. Dry, undisturbed batts or loose fill still deliver every R they ever did, and new insulation goes straight over the top — blown-in over batts is the standard top-up. Removal only makes sense for insulation that is wet, mouldy, smoke- or pest-damaged. Everything else is paying to throw away R you already own.
Compressing batts into a smaller cavity
A batt's R-value lives in its loft. An R-19 batt made for a 6¼ in cavity squeezed behind pipes into 3½ in performs closer to R-13 — you paid for 19 and installed 13. Match the batt to the cavity depth, or split the R across two thinner batts. The same goes for storage boards laid over attic insulation: they crush the layer beneath them.
Blocking the soffit vents
Blown insulation drifts, and without baffles (vent chutes) it piles into the eaves and seals the soffit vents the roof depends on. A starved attic ventilation system means condensation on the roof deck, mould, and ice dams in cold zones. Baffles cost a couple of dollars each and are stapled in before the hose comes out — not after.
Insulating before air-sealing
Insulation slows heat moving through a ceiling; it does nothing about warm air flowing around it through gaps at top plates, plumbing stacks, recessed lights and the attic hatch. Those bypasses can carry more heat than the ceiling itself. Seal them with foam and caulk first — it is the cheapest hour of the whole job and the one most often skipped.
Insulation Calculator — Frequently Asked Questions
How many bags of blown-in insulation do I need for a 1,200 sq ft attic?
It depends on the R you are adding. Topping up from R-11 to the R-60 recommended for an uninsulated attic in Zone 5 means adding R-49: blown fiberglass covers about 27.6 sq ft per bag at that depth, so with a 5% waste allowance the job takes 46 bags. From empty (R-0 → R-60) it takes 56 bags, and the same top-up in cellulose takes 89 bags — cellulose packs more R per inch but far less coverage per bag. By Owens Corning's AttiCat chart the same R-49 top-up takes about 30 bags of AttiCat (32 with waste), because AttiCat bags cover more per bag. The insulation calculator above runs this for your area and zone.
How does an insulation calculator work out how many bags or batts to buy?
It multiplies the area by the R-value you still need — target R minus existing R — and divides by what one package delivers. For loose fill, one bag of blown fiberglass delivers roughly 1,350 sq ft of R-1 coverage, so bags = area × R to add ÷ 1,350. It then adds a waste allowance — 5% by default, 5–10% is the typical range — and rounds up to whole packages. For batts and boards it divides the area plus waste by the package coverage, rounds up, and multiplies by the number of layers when one layer cannot reach the target. A heat-loss model (area × heating degree days × 24 × the change in 1/R) then estimates the annual heating saving and simple payback.
What R-value should my attic, walls and floor have?
Recommended levels rise with climate zone. Attics (uninsulated): R-30 in Zone 1, R-49 in Zones 2–3 and R-60 in Zones 4–8, per ENERGY STAR recommended levels aligned with IECC 2021. Wall cavities: R-13 in Zones 1–2, R-20 in Zones 3–5, R-21 in Zones 6–8. Floors over unheated space: R-13 in Zones 1–2, R-19 in Zones 3–4, R-30 in Zones 5–6, R-38 in Zones 7–8. Local code for new work can differ.
How much does it cost to insulate a 1,200 sq ft attic in 2026?
Topping up from R-11 to R-60 with blown-in fiberglass costs about $2,648 professionally: 46 bags at $38 is $1,748 of material (including a 5% waste allowance) plus $900 of labour at $0.75 per sq ft — labour is 34% of the total, which works out to $2.21 per sq ft all-in. DIY, the same job is about $1,748, materials only, and most big-box stores lend the blowing machine free with a minimum bag purchase (standalone rental runs about $75 a day). Rates are 2026 national benchmarks — local quotes vary.
Can I put new insulation on top of old insulation?
Yes — and you usually should. R-values add: R-11 of old batts plus R-49 of new blown-in gives R-60. Leave sound, dry insulation in place; blown-in over batts is the standard attic top-up because it fills the gaps around joists. Remove old insulation only if it is wet, mouldy, pest- or fire-damaged. And never compress insulation to make it fit — a squeezed batt loses R-value.
How deep will my insulation be, in inches?
Depth is R-value divided by the material's R per inch. Blown fiberglass gives about R-2.5 per inch, so adding R-49 means blowing about 19.6 in deep. Blown cellulose ≈ R-3.7 per inch (R-49 ≈ 13.2 in), fiberglass batts ≈ R-3.4, mineral wool ≈ R-4.2 and XPS board R-5 per inch. Manufacturer depth charts govern for their own products — Owens Corning AttiCat reaches R-49 at 17 in. Installers staple depth markers to the trusses so the blown depth can be checked at a glance. If you are measuring what you already have, enter the depth in the calculator's depth fields and it works the R out for you.
How much money will attic insulation save, and how fast does it pay back?
It depends mostly on what you start from, because heat loss follows 1/R. Adding R-19 over a 400 sq ft ceiling in Zone 4 (about 4,600 heating degree days, heat at $1.30 per therm) saves about $166 a year over an empty cavity — a $420 job pays back in about 2.5 years. The same R-19 layer over existing R-11 saves only about $32 a year, a payback of about 13 years. The first R you add does the heavy lifting; each further layer saves less than the one before. The calculator runs this model live for your zone, area and R-values.
How much waste should I allow, and how much of the cost is labour?
Allow 5% waste as a floor and up to 10% for cut-up spaces with many small bays — the calculator applies 5% by default to every package count before rounding up, and you can edit it. On the default 1,200 sq ft pro job, labour is $900 of the $2,648 total — 34% — at $0.75 per sq ft for blown-in. Batt labour runs $0.85 per sq ft and rigid board $1.15, because every piece is cut and fitted by hand.
Do I need to rent a blowing machine for blown-in insulation?
Yes for loose fill — batts are the only no-machine route. Most big-box stores lend the blower free for 24 hours with a minimum bag purchase (often 10 bags); buy fewer and standalone rental runs about $75 a day plus a refundable deposit. Blowing is a two-person job: one person feeds bags into the hopper, the other works the hose in the attic.